• Title of article

    Multitemporal thermal analysis to detect moisture on a building façade

  • Author/Authors

    Lerma، نويسنده , , José L. and Cabrelles، نويسنده , , Miriam and Portalés، نويسنده , , Cristina، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    8
  • From page
    2190
  • To page
    2197
  • Abstract
    It is well known that the content of water does affect materials behaviour and may cause important damages to buildings, including structural deterioration. Thermography is a non-intrusive imaging technique that allows the inspection of different materials based on their surface temperatures. Within an appropriate thermal analysis, moisture and other structural damages can be detected. The present research work deals with multitemporal thermal analysis to detect moisture on buildings, as well as other alterations. Two different approaches are tested to determine the effectiveness on the moisture surveys, one simple based on image differences, and another more sophisticated based on principal components analysis (PCA). The results are tested at the front door of the Arenberg Castle (Leuven, Belgium). Some moisture maps are derived and used to determine the reliability of either the computation of image differences or the PCA to carry out semi-automatically moisture surveys on architectural façades. The latter method is proven to be superior when using thermal imagery acquired at different times.
  • Keywords
    thermography , Moisture , Principal components analysis