Title of article :
Study of self consolidating concretes stability during their placement
Author/Authors :
Vanhove، نويسنده , , Y. and Djelal، نويسنده , , C. and Schwendenmann، نويسنده , , G. and Brisset، نويسنده , , P.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
8
From page :
101
To page :
108
Abstract :
Because of their great fluidity, Self Consolidating Concretes (SCCs) can be poured into large-sized formworks or through a thick iron framework without using vibration. However, a wrong proportion of concrete or an unsuited method of filling can generate a heterogeneous distribution of its various constituents. Numerous devices have been developed to locate the heterogeneities. Some of them allow on-site measurement, while others require sampling. A technique of gamma-ray attenuation was adapted to measure local changes in concrete density. SCC with different castings process in formworks of 15 m long and 5 m high and others with 10 m high and 5 m long were investigated. Test results show a variation of aggregates concentration in the concrete wall according to the flowing distance or to the pouring height. The paste thickness at the wall could be appreciated with this technique.
Keywords :
Segregation , Gammadensimetry , Self consolidating concrete , homogeneity
Journal title :
Construction and Building Materials
Serial Year :
2012
Journal title :
Construction and Building Materials
Record number :
1633515
Link To Document :
بازگشت