• Title of article

    Hot box measurements of pumice aggregate concrete hollow block walls

  • Author/Authors

    Kus، نويسنده , , Hülya and ضzkan، نويسنده , , Ertan and Gِcer، نويسنده , , ضzgür and Edis، نويسنده , , Ecem، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    9
  • From page
    837
  • To page
    845
  • Abstract
    Due to its relatively low thermal conductivity characteristics and being a local product, pumice aggregate concrete (PAC) blocks are increasingly used as a masonry wall unit in Turkey. However, there is limited technical and scientific knowledge on hygrothermal performance of PAC blocks. A research project is conducted to study hygrothermal performance of PAC block walls using a calibrated hot box method. Temperature and humidity measurements were carried out at the surfaces of the test wall and in the hollows of blocks on different courses. The results, in general, indicate that the hollows of blocks perform better in terms of thermal transmittance than the lightweight solid parts of them. Noticeable changes are observed in hygrothermal behaviour of the lower and the upper courses depending on the indoor and outdoor climate test conditions. The heterogeneous material and rough surface characteristics of the blocks, in addition to the wet construction type of block wall are the most problematic issues that make measurements and assessments difficult.
  • Keywords
    Pumice , Concrete block , Hygrothermal performance , Hot box , Measurement
  • Journal title
    Construction and Building Materials
  • Serial Year
    2013
  • Journal title
    Construction and Building Materials
  • Record number