Title of article :
Bond between powder type self-compacting concrete and steel reinforcement
Author/Authors :
Pop، نويسنده , , Ioan and Schutter، نويسنده , , Geert De and Desnerck، نويسنده , , Pieter and Onet، نويسنده , , Traian، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Abstract :
The paper reports an investigation on the bond behavior between steel reinforcement and powder-type self-compacting concrete (SCC). A total of 135 pull-out cubes were cast by using four self-compacting mixes (SCC) and two vibrated concretes (VC). The main analyzed parameters were the concrete compressive strength, the reinforcement bar diameter, the embedded length of bars and cement/limestone ratio. The results showed that the ultimate bond strength can be greater in self-compacting concrete compared to vibrated concrete. At the same load level the bars in SCC tend to present a smaller slip than in VC. Considering the influence of bar diameter and embedded length, it seems that SCC and VC behave in a similar way.
Keywords :
Bond strength , Bar diameter , Self-compacting concrete , Embedded length , Pull-out test
Journal title :
Construction and Building Materials
Journal title :
Construction and Building Materials