• Title of article

    Performance evaluation of the post-installed anchor for sign structure in South Korea

  • Author/Authors

    Kim، نويسنده , , Jin-Sup and Jung، نويسنده , , Woo-Young and Kwon، نويسنده , , Min-Ho and Ju، نويسنده , , Bu-Seog، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    11
  • From page
    496
  • To page
    506
  • Abstract
    In this study, numerous experimental tests for post-installed anchor systems used for sign structures in South Korea, drilled in hardened concrete were conducted in order to estimate pull-out and shear strength of the anchor based on three mechanical properties – torque ratio, embedment depth and diameter. In the pull-out tests, the pull-out strength of the anchor system depends significantly on all the three aforementioned parameters while in the shear tests, it was informed that the shear strength is not affected by torque ratio. It was also found that concrete cone failure or damage mechanism was generally observed during and after pull-out tests and in shear strength tests and that the anchor systems fail prior to the failure in the existing primary structural system. Furthermore, 3D finite element model for the anchor systems was created by ABAQUS to validate the experimental results using numerical analysis. It is shown that the formulated finite element model can be used to closely predict the load–displacement relationships as observed in the experimental tests. Further, we also propose a criterion for evaluating limit states to enable reliable design of the anchor systems using probabilistic fragility methodologies.
  • Keywords
    Post-installed anchor , TORQUE , fragility , Pull-out and shear test
  • Journal title
    Construction and Building Materials
  • Serial Year
    2013
  • Journal title
    Construction and Building Materials
  • Record number

    1635101