• Title of article

    Tensile behavior of post-installed chemical anchors embedded to low strength concrete

  • Author/Authors

    Yilmaz، نويسنده , , Salih and ضzen، نويسنده , , Muhammet Ali and Yardim، نويسنده , , Yavuz، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    6
  • From page
    861
  • To page
    866
  • Abstract
    In the scope of this paper, tensile capacities of post-installed chemical anchors embedded to 5.9 and 10.9 MPa concrete blocks are investigated. Pull-out tests are applied to 80 ductile steel bars (S420a). For the anchor diameters, 12, 16 and 20 mm are chosen. On the other hand, 10, 15 and 20 times the bar diameter are selected as free-edge distance and embedment depth for monotonic tensile loading tests. The results indicate that installation of anchors into low-strength concrete with sufficient embedment depth and free-edge distance is not unsafe as previously expected. To obtain ductile failure in low strength concrete, free-edge distance and embedment depth of minimum 15 times the anchor diameter should be required. Furthermore, a comparison of test results with ACI 318 capacities is done and it is observed that ACI 318 has quite an over-conservative approach for the tensile capacity of post-installed anchors when low-strength concrete is considered.
  • Keywords
    Chemical anchors , Tensile capacity , Axial behavior , Free edge distance , Low-strength concrete , Embedment depth
  • Journal title
    Construction and Building Materials
  • Serial Year
    2013
  • Journal title
    Construction and Building Materials
  • Record number