• Title of article

    Bonding and toughness properties of PVA fibre reinforced aqueous epoxy resin cement repair mortar

  • Author/Authors

    Luo، نويسنده , , Jianlin and Li، نويسنده , , Qiuyi and Zhao، نويسنده , , Tiejun and Gao، نويسنده , , Song and Sun، نويسنده , , Shengwei، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    6
  • From page
    766
  • To page
    771
  • Abstract
    Orthogonal experiment with three elements (one of three levels) was employed to optimise the experimental parameters for the repair performances of PVA fibre reinforced aqueous epoxy resin cement mortar (PVA-FPCM) by the analysis of means and variances. The experimental parameters were selected as polymer-cement ratio (P/C), water-cement ratio (W/C), and PVA fibre loading (wPVA) in this paper. Results indicate that, wPVA has the greatest influence on the fracture toughness (flexural/compressive strength ratio fb/fc), the bond strength (fAT), and the impact toughness (the number of repeated impact to the initial crack ni, to the final crack nf). The optimal combination of the process parameters for a high-performance repair mortar through further confirmatory experimental is P/C at 0.20, W/C at 0.35, and wPVA at 1%.
  • Keywords
    Orthogonal experiment , Bond property , Toughness property , PVA fibre , Polymer cement repair mortar
  • Journal title
    Construction and Building Materials
  • Serial Year
    2013
  • Journal title
    Construction and Building Materials
  • Record number

    1635615