Title of article :
Electric arc furnace oxidizing slag mortar with volume stability for rapid detection
Author/Authors :
Kuo، نويسنده , , Wen-Ten and Shu، نويسنده , , Chun-Ya and Han، نويسنده , , Ye-Wei، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
Electric arc furnace oxidizing slag (EOS), replacing 10%, 20%, 30%, 40% and 50% of the sand by weight, begins the autoclave expansion. Heating catalysis (100 °C), accompanied by X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis, verifies the effect of the catalytic test. The results showed that when the EOS replaces the sand, particularly at ratios higher than 30%, there is the risk of expansion. The expansion of the normal mixed destruction alert value is approximately 0.12–0.13%. Reactions are dependent on the temperature and catalytic time, which are proportional. SEM images of the heating catalysis show the generation of Ca(OH)2 near the extrusion caused by the hydration products. Free lime (f-CaO) hydration generates Ca(OH)2, which is the main reason for the expansion rupture.
Keywords :
Rapid Detection , Volume stability , Free lime (f-CaO) , Electric arc furnace oxidizing slag (EOS)
Journal title :
Construction and Building Materials
Journal title :
Construction and Building Materials