Title of article
Structural performance of shear resisting connections between cold-formed steel sections using web cleats of cold-formed steel strip
Author/Authors
Chung، نويسنده , , K.F. and Lawson، نويسنده , , R.M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
17
From page
1350
To page
1366
Abstract
The paper presents an investigation on the structural performance of shear resisting connections between cold-formed steel sections where web cleats of cold-formed steel strips are used to attach beams to supporting beams and columns. A total of 24 connection tests with four different connection configurations were carried out; three modes of failure were identified:•
e of fasteners
buckling of cold-formed steel web cleats or webs of supported beams, and
l torsional buckling of cold-formed steel web cleats
ructural performance of the cold-formed steel web cleats in four different connection configurations is presented in detail. It is demonstrated that cold-formed steel web cleats may be used with bolts or self-drilling self-tapping screws as practical shear resisting connections in building construction. A set of design rules is formulated in accordance with both BS5950: Part 5 and Eurocode 3: Part 1.3 after calibration against test data. The rationalized usage of cold-formed steel web cleats allows simple and effective connections to be formed between cold-formed steel sections leading to improved buildability.
Keywords
cold-formed steel , Simple connections , Shear resisting connections , Web cleats , Design rules , laboratory tests
Journal title
Engineering Structures
Serial Year
2000
Journal title
Engineering Structures
Record number
1638605
Link To Document