• Title of article

    Structural performance of shear resisting connections between cold-formed steel sections using web cleats of cold-formed steel strip

  • Author/Authors

    Chung، نويسنده , , K.F. and Lawson، نويسنده , , R.M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    17
  • From page
    1350
  • To page
    1366
  • Abstract
    The paper presents an investigation on the structural performance of shear resisting connections between cold-formed steel sections where web cleats of cold-formed steel strips are used to attach beams to supporting beams and columns. A total of 24 connection tests with four different connection configurations were carried out; three modes of failure were identified:• e of fasteners buckling of cold-formed steel web cleats or webs of supported beams, and l torsional buckling of cold-formed steel web cleats ructural performance of the cold-formed steel web cleats in four different connection configurations is presented in detail. It is demonstrated that cold-formed steel web cleats may be used with bolts or self-drilling self-tapping screws as practical shear resisting connections in building construction. A set of design rules is formulated in accordance with both BS5950: Part 5 and Eurocode 3: Part 1.3 after calibration against test data. The rationalized usage of cold-formed steel web cleats allows simple and effective connections to be formed between cold-formed steel sections leading to improved buildability.
  • Keywords
    cold-formed steel , Simple connections , Shear resisting connections , Web cleats , Design rules , laboratory tests
  • Journal title
    Engineering Structures
  • Serial Year
    2000
  • Journal title
    Engineering Structures
  • Record number

    1638605