pH-Metric method for acid number determination in hydraulic oils without titration
Author/Authors :
Strochkova، نويسنده , , E. and Tur’yan، نويسنده , , Ya.I. and Kuselman، نويسنده , , I.، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 1999
Pages :
5
From page :
1135
To page :
1139
Abstract :
A heptane-mediated extraction of acids from hydraulic oils is proposed for pH-metric acid number determination without titration. The acids are extracted in the reagent consisting of triethanolamine and potassium nitrate dissolved in water and isopropanol. The use of heptane allows us to overcome the influence of additives in the hydraulic oil on the glass electrode. Simultaneously the extraction of acids from the oil into the water–isopropanol phase is simplified. The method is validated and suitable metrological characteristics of the acid number determination are obtained.
Keywords :
Acid number , pH-Metry , Hydraulic oils , Metrological parameters