Title of article
Shaketable tests of a cold-formed steel shear panel
Author/Authors
Kim، نويسنده , , Tae-Wan and Wilcoski، نويسنده , , James and Foutch، نويسنده , , Douglas A. and Lee، نويسنده , , Moon Sung، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
9
From page
1462
To page
1470
Abstract
Buildings composed of cold-formed steel framing systems are popular in many parts of the United States. Box-shaped columns can be built-up from cold-formed thin-walled channels. Latered bracing is often provided by cross-bracing using thin tension-only straps in selected bays. Although several static cyclic tests of individual shear panels have been conducted by several investigators, no dynamic tests have previously been conducted. Results of shaketable tests of a full-scale two-story one-bay structure are reported herein. During the large amplitude tests, the cross-bracing straps showed very ductile but highly pinched hysteresis behavior. The columns that were fixed at the top and bottom provided limited strength, stiffness, and energy dissipation because of local buckling of the thin-walled members. Analytical results reproduced the measured behavior relatively well.
Keywords
cold-formed steel , Shaketable test , Strap , shear panel
Journal title
Engineering Structures
Serial Year
2006
Journal title
Engineering Structures
Record number
1640825
Link To Document