Title of article :
Flow-injection chemiluminescence determination of epinephrine in pharmaceutical preparations using raw apple juice as enzyme source
Author/Authors :
Micha?owski، نويسنده , , J. and Ha?aburda، نويسنده , , P.، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2001
Pages :
7
From page :
1165
To page :
1171
Abstract :
Raw apple juice exhibits the activity of polyphenol oxidase which can be employed for the determination of mono-, di- and polyhydric phenols. The chemiluminescence detection in the two-channel manifold was used to develop the new procedure for determination of epinephrine. Epinephrine can be determined by this method in pharmaceutical preparations in concentration ranges 1.0–10.0 and 10.0–25.0 mg l−1, with a detection limit of 0.2 mg l−1. Good selectivity against typical antioxidants and other coexisting substances was achieved. Relatively slow loss of the enzyme activity was observed during 1 week. The proposed method is very simple. Fresh juice solution from one apple can be prepared in 10 min and used for at least 8 h with excellent precision. Consumption of luminol solution was 0.15 ml min−1. The throughput was 20 samples per hour.
Keywords :
Chemiluminescence , Flow-injection , Polyphenol , oxidase , Epinephrine , Simplex optimization , Apple juice
Journal title :
Talanta
Serial Year :
2001
Journal title :
Talanta
Record number :
1642042
Link To Document :
بازگشت