Title of article
Design recommendations for bond between GFRP/steel wire composite rebars and concrete
Author/Authors
Hao، نويسنده , , Qingduo and Wang، نويسنده , , Yanlei and Ou، نويسنده , , Jinping، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
8
From page
3239
To page
3246
Abstract
Due to significant advantages over GFRP rebars, namely high tensile strength, high elastic modulus, and good ductile properties, GFRP/steel wire composite rebars offer a superior alternative to ordinary steel rebars. However, experimental researches on this new type of rebar have been limited, especially those on the bond performance. This research is designed to investigate the bond behavior between GFRP/steel wire composite rebars and concrete. According to American Concrete Institute (ACI) code, a total of 180 pull-out specimens were tested under monotonic static loading conditions. The test parameters were the rebar rib spacing, rebar diameter, embedded length, concrete compressive strength, concrete cover thickness, and concrete cast depth. Based on the numerical analysis of the test results, new criteria for acceptable bond performance of GFRP/steel wire composite rebars to concrete were developed. Designed recommendations for the modification factor of concrete cover thickness, the modification factor of concrete cast depth, and the critical value of bond slip at both free and loaded ends were derived. The calculation formula of bond strength and the basic development length were proposed, and the calculation principle of development length of concrete structures reinforced with GFRP/steel wire composite rebars was suggested.
Keywords
Concrete , Bond behavior , Pull-out test , GFRP/steel wire composite rebar , Design recommendations
Journal title
Engineering Structures
Serial Year
2008
Journal title
Engineering Structures
Record number
1643466
Link To Document