Abstract :
Two different spectrofluorimetric methods for the determination of piroxicam (PX) in serum are presented and discussed. One of them is based on the use of three-way fluorescence data and multivariate calibration performed with parallel factor analysis (PARAFAC) and self-weighted alternating trilinear decomposition (SWATLD). This methodology exploits the so-called second-order advantage of the three-way data, allowing to obtain the concentration of the studied analyte in the presence of any number of uncalibrated (serum) components. The method was developed following two different procedures: internal standard addition and external calibration with standard solutions, which were compared and discussed. The second approach investigated is based on the combination of solid-phase extraction (SPE) and room temperature fluorimetry. Both methods here presented yield satisfactory results. The concentration range in which PX could be determined in serum was 1–10 μg ml−1. The limits of quantification for the experimental solutions using the chemometric approach were 0.09 μg ml−1 for the standard addition mode and 0.12 μg ml−1 using external calibration (both for PARAFAC and SWATLD algorithms). In the solid-surface fluorimetric method, the calibration graph was linear up to 0.22 μg ml−1 and the limit of quantification was 0.02 μg ml−1.
Keywords :
Solid-phase-extraction , Piroxicam , Spectrofluorimetry , Three-way multivariate calibration