Title of article :
Potentiometric membrane sensors based on zirconyl(IV) phthalocyanine for detection of sulfosalicylic acid
Author/Authors :
Shahrokhian، نويسنده , , Saeed and Taghani، نويسنده , , Abdollah and Hamzehloei، نويسنده , , Ali and Reza Mousavi، نويسنده , , S.، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2004
Abstract :
A metallophthalocyanine complex with zirconium(IV) ion in the center (as an oxo-zirconium, Zr=O, group) was used in poly vinyl chloride (PVC) membranes for the selective detection of 5-sulfosalicylic acid (SSA). The resulting electrodes demonstrate Nernstian responses over a wide range of sulfosalicylic acid concentration (10−6 to 10−1 mol dm−3) with a slope of about −29 mV per decade. The influence of lipophilic ion-exchanger sites on the response properties of the electrodes was investigated. The optimal potentiometric response was observed for the electrode in the presence of about 150 mol% of cationic additive (relative to ionophore) in the phase membrane. The electrodes have a fast response time, micromolar detection limit and good long-term stability (more than 2 months). The feasibility of the application of these sensors for the potentiometric titration of iron in solutions that were prepared from magnetite samples was investigated.
Keywords :
Ion selective electrodes , Sulfosalicylic acid , Zirconyl(IV) phthalocyanine , Potentiometry