Title of article :
Measurement of PCDDs, PCDFs, and non-ortho-PCBs by comprehensive two-dimensional gas chromatography-isotope dilution time-of-flight mass spectrometry (GC × GC-IDTOFMS)
Author/Authors :
Focant، نويسنده , , Jean-François and Reiner، نويسنده , , Eric J and MacPherson، نويسنده , , Karen and Kolic، نويسنده , , Terry and Sjِdin، نويسنده , , Andreas and Patterson Jr.، نويسنده , , Donald G and Reese، نويسنده , , Shawn L and Dorman، نويسنده , , Frank L and Cochran، نويسنده , , Jack، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2004
Abstract :
Comprehensive two-dimensional gas chromatography with isotope-dilution time-of-flight mass spectrometry (GC × GC-IDTOFMS) was used to measure polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofuran (PCDF), and coplanar polychlorinated biphenyl (cPCB) concentrations in ash, sediment, vegetation, and fish samples. The GC × GC capability was achieved by using a quad jet, dual stage, thermal modulator. Zone compression of the GC peaks from modulation resulted in a significant increase of the signal intensity over classical GC-IDTOFMS. The GC × GC column set used an Rtx-Dioxin 2 phase as the first dimension (1D) and an Rtx-500 as the second dimension (2D). The chromatographic separation of the 17 PCDD/Fs and the 4 cPCBs was attained in 1D except for 2,3,7,8-TCDD and CB126 for which deconvoluted ion currents (DIC) were required to be reported separately. The Rtx-500 phase separated the bulk matrix interfering compounds from the target analytes in 2D. The instrumental limit of detection (iLODs) was 0.5 pg for 2,3,7,8-TCDD. The calibration curves showed good correlation coefficients for all the compounds investigated in the concentration range of 0.5–200 pg. GC × GC-IDTOFMS results compared favorably to those from conventional isotope-dilution one-dimensional gas chromatography-high resolution mass spectrometry (GC-IDHRMS). The comprehensive mass analysis of the TOFMS further permitted the identification of other contaminants of concern in the samples.
Keywords :
Polychlorinated dibenzofurans (PCDFs) , Comprehensive two-dimensional gas chromatography (GC × GC) , Coplanar polychlorinated biphenyls (cPCBs) , Time-of-flight mass spectrometry (ToFMS) , Polychlorinated Dibenzo-p-Dioxins (PCDDs)