Title of article :
Determination of nickel in natural waters by FAAS after sorption on octadecyl silica membrane disks modified with a recently synthesized Schiff’s base
Author/Authors :
Khorrami، نويسنده , , Afshin Rajabi and Naeimi، نويسنده , , Hossein and Fakhari، نويسنده , , Ali Reza، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2004
Abstract :
A simple, highly sensitive, accurate and selective method for the determination of trace amounts of Ni2+ ions in water samples is proposed. The method is based on the separation and preconcentration of Ni2+ on an octadecyl-bonded silica (ODBS) membrane disk modified by a recently synthesized Schiff’s base N,N′-bis (3-methylsalicylidene) ortho phenylene diamine (MSOPD) at pH 7. The synthesis of this extractant ligand is also described. The retained nickel on the membrane was eluted with 2×5 ml 0.5 M HNO3 and measured by flame atomic absorption spectrometry (FAAS) at 232.0 nm. The extraction efficiency and the influence of the type and least amount of eluent for the stripping of Ni2+ from the disks, pH, flow rates of sample solution and eluent, amount of MSOPD, effect of other ions, and breakthrough volume were evaluated. The maximum capacity of the membrane disks modified by 3 mg of MSOPD was found to be 146±4 μg Ni2+. The 3σ limit of detection of the method was 30 ng per 1000 ml and also an enrichment factor of 250 was obtained. The proposed method has been applied to the determination of nickel in several water samples with satisfactory results.
Keywords :
Nickel determination , SPE , N , Preconcentration , FAAS , Separation , N?-bis (3-methylsalicylidene) ortho phenylene diamine