Title of article :
Modeling and validation of a wall-window retrofit system under blast loading
Author/Authors :
Riedel، نويسنده , , W. and Fischer، نويسنده , , K. and Kranzer، نويسنده , , C. E. Erskine، نويسنده , , J. and Cleave، نويسنده , , R. and Hadden، نويسنده , , D. and Romani، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
11
From page :
235
To page :
245
Abstract :
This paper describes the three step model development of a masonry retrofit and window system under external blast loading. First, basic deformation and failure mechanisms are analyzed using finite element methods. SDOF models are then derived separately for the structural response of retrofitted masonry and window systems and validated in full-scale range and shock tube tests. In a third step the model is expanded to two degrees of freedom to predict the coupled behavior. This paper focuses on the engineering models and the derivation of the system parameters. The algorithms are implemented in a PC-based tool for easy and fast application.
Keywords :
SDOF , Masonry retrofit , Inverse analysis , PC based engineering tool , TDOF , blast
Journal title :
Engineering Structures
Serial Year :
2012
Journal title :
Engineering Structures
Record number :
1646745
Link To Document :
بازگشت