Title of article
Distortion-induced stress investigation of double angle stringer-to-floorbeam connections in railroad bridges
Author/Authors
Guyer، نويسنده , , Robert C. and Laman، نويسنده , , Jeffrey A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
9
From page
104
To page
112
Abstract
Research has shown that double angle stringer-to-floorbeam connections in riveted railway bridges are susceptible to fatigue cracking caused by secondary, distortion-induced stress. This stress, caused by stringer end rotation is not easily calculable, therefore more detailed analysis techniques are needed to quantify connection behavior. The present study was initiated to determine the effect that connection parameters: (1) gage length of the outstanding angle leg, (2) angle depth, (3) angle thickness, and (4) stringer length have on moment–rotation behavior and stress concentrations from a typical 286,000 pound railcar load. Seventy-two unique double angle connection configurations were investigated using 3D and 2D finite element analysis software. Maximum principal stress in the connection angle was investigated in each analysis case and a subsequent stress prediction equation was developed through linear regression analysis. The proposed equation is a function of connection parameters and provides an easily calculable and effective method to predict the magnitude of stress range in connection angles. This facilitates fatigue life evaluation without the need for rigorous analysis.
Keywords
Distortion induced stress , Double angle connection , Stringer to floorbeam connection , Riveted bridge , Distortion induced fatigue , Railroad bridge
Journal title
Engineering Structures
Serial Year
2012
Journal title
Engineering Structures
Record number
1646777
Link To Document