Title of article
Effect of transient strain on strength of concrete and CFT columns in fire – Part 2: Simplified and numerical modelling
Author/Authors
Huang، نويسنده , , Shan-Shan and Burgess، نويسنده , , Ian W.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
11
From page
389
To page
399
Abstract
This paper presents finite element analysis on columns of concrete and concrete-filled tubular section. This study has been conducted with Vulcan, a specialist structural fire engineering FE program, which has been further developed to incorporate the transient strain of concrete. The implementation of transient strain in Vulcan has been validated against a Shanley-like simplified model. A further extension of the simplified model has been carried out in order to provide direct comparability with the FE modelling. The effects of transient strain, considering thermal gradients through the column cross-section, have been evaluated with both the simplified and FE models. Finally, parametric studies on concrete-filled tubular columns, considering the effects of slenderness ratio, reinforcement, the steel casing and thermal gradient within the cross-section, have been conducted using Vulcan.
Keywords
Transient strain , Concrete-filled tubular column , Shanley-like model , Structural fire engineering
Journal title
Engineering Structures
Serial Year
2012
Journal title
Engineering Structures
Record number
1647437