Title of article
Preparation and evaluation of a large-volume radial flow monolithic column
Author/Authors
Yang، نويسنده , , Changlong and Wei، نويسنده , , Yuanlong and Zhang، نويسنده , , Qinghe and Zhang، نويسنده , , Weibing and Li، نويسنده , , Tong-Liang Hu، نويسنده , , Haoquan and Zhang، نويسنده , , Yukui، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2005
Pages
7
From page
472
To page
478
Abstract
In this study, a 38 mL monolith with homogeneous porous structure was produced by a single polymerization from glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) in the presence of porogens and an initiator. The uniform temperature distribution within the reaction system was achieved by adding reactant mixture continuously and enhancing the heat transfer ability of the polymerization system. Homogeneous porous structure in the monolith was proved by SEM and the pore size distribution profiles measured by mercury intrusion porosimetry. Experimental results from proteins separation indicated that the dynamic capacity and resolution of radial flow monolithic column were independent of flow rates. Furthermore, the pressure drop on the column was linearly dependent on the flow rate and did not exceed 1.7 MPa even at a flow rate of 50 mL/min, which proved that the prepared monolith could be used in the quick separation and preparation of biopolymers.
Keywords
GMA–EDMA , Temperature controlling , Radial Flow , Porous structure , Monolithic column
Journal title
Talanta
Serial Year
2005
Journal title
Talanta
Record number
1648054
Link To Document