Title of article :
Molecularly imprinted TiO2 thin film using stable ground-state complex as template as applied to selective electrochemical determination of mercury
Author/Authors :
Liu، نويسنده , , Zhihang and Huan، نويسنده , , Shuangyan and Jiang، نويسنده , , Jianhui and Shen، نويسنده , , Guoli and Yu، نويسنده , , Ruqin، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2006
Abstract :
Molecular recognition sites for mercury ions were imprinted in TiO2 film using stable ground-state complex of 1-amino-8-naphtol-3,6-disodium sulfonate (ANDS) and mercury ions as template. The complex ratio between mercury ions and ANDS was estimated to be 2:1. Compared with the controlled and pure TiO2 electrodes, the imprinted electrode revealed selectivity towards the imprinted ions. Linear calibration plots for mercury ions were obtained and the regression equation was Ip (μA) = 4.29 × 10−7 + 19.40 [Hg2+] with a detection limit of 3.06 × 10−9 mol/l. The imprinted electrode could be used for more than 1 month. Recoveries were calculated at both high and low concentrations, with a mean recovery of 99.6%.
Keywords :
Imprinted thin film , Stable ground-state complex , LSV , Sol–gel , Sensor