Title of article
ED XRF analysis of precious metallic alloys with the use of combined FP method
Author/Authors
Cernohorsky، نويسنده , , Tomas and Pouzar، نويسنده , , Miloslav and Jakubec، نويسنده , , Karel، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2006
Pages
4
From page
538
To page
541
Abstract
The “combined” FP method, which combines standardless FP method with empirical calibration, was applied to the analysis of Ir–Pt, Rh–Pt, Rh–Pd–Pt and Rh–Ir–Pt disk samples and Pt–Rh thermocouple wire. Four reference materials of binary Pt–Ir system, eight Pt–Rh systems, eight reference materials of ternary Pt–Ir–Rh system and 10 Pt–Rh–Pd systems were used for calibration of “combined” FP XRF method. Results of mentioned method agreed well with certified values, or ICP OES results respectively. For determination of elements, which were not present or certified in calibration standards (Ru in Rh–Pt–Pd disc and Fe in Pt–Rh thermocouple wire) the standardless FP method was used. This approach provides good results as well.
Keywords
ED XRF , fundamental parameters , Precious metals
Journal title
Talanta
Serial Year
2006
Journal title
Talanta
Record number
1649993
Link To Document