Title of article :
A dose-point-kernel model for a low energy gamma-emitting stent in a heterogeneous medium
Author/Authors :
Janicki، Christian نويسنده , , Duggan، Dennis M. نويسنده , , Rahdert، David A. نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
-1396
From page :
1397
To page :
0
Abstract :
A computer dose model for a low energy gamma-emitting stent in a heterogeneous medium is described. The method is based on the Sievert model which is adapted to the dose-point-kernel (DPK) model to compute the dose distribution about filtered gamma sources (Sievert-DPK model). The new gamma stent model can take into account effects such as the metallic wire attenuation and the presence of dense calcified plaque in a stented artery. The Sievert-DPK model is tested against numerical simulations around cylindrical shell sources with dimensions comparable to those of a stent using a Monte Carlo transport code. For low energy gamma sources (Cs-131 and Pd-103), it is shown that the Sievert-DPK model is consistent with the Monte Carlo results to about 5%-10% for distances up to 5 mm from the cylindrical surface and 2.5 mm beyond the cylinder edges. These results indicate that the Sievert-DPK model may be useful to predict the dose in intravascular therapy applications for heterogeneous systems consisting of soft tissue, metal and dense plaque.
Keywords :
Fault current limiter , short circuit current , transient over voltage , power quality
Journal title :
MEDICAL PHYSICS
Serial Year :
2001
Journal title :
MEDICAL PHYSICS
Record number :
1650
Link To Document :
بازگشت