Title of article
Application of matrix solid phase dispersion to the determination of imidacloprid, carbaryl, aldicarb, and their main metabolites in honeybees by liquid chromatography–mass spectrometry detection
Author/Authors
Totti، نويسنده , , S. and Fernلndez، نويسنده , , M. and Ghini، نويسنده , , S. and Picَ، نويسنده , , Y. and Fini، نويسنده , , F. and Maٌes، نويسنده , , J. and Girotti، نويسنده , , S.، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2006
Pages
6
From page
724
To page
729
Abstract
A method based on matrix solid phase dispersion (MSPD) using C18 as dispersant and dichloromethane–methanol as eluent and liquid chromatography–atmospheric pressure chemical ionization–mass spectrometry (LC–APCI–MS) has been developed for the simultaneous determination of imidacloprid, 6-chloronicotinic acid, carbaryl, aldicarb, aldicarb sulfoxide, and aldicarb sulfone in honeybees.
oposed method was compared with liquid–liquid extraction (LLE) combined with LC–APCI–MS analysis. Spiked blank samples were used as standards to counteract the matrix effect observed in the chromatographic determination. Recovery studies were performed at different fortification levels. Average recoveries by MSPD varied from 61% of 6-chloronicotinic acid to 99% of aldicarb sulfoxide and relative standard deviations were equal or lower than 14%. Limit of detections ranged from 0.004 mg kg−1 for imidacloprid to 0.09 mg kg−1 for 6-chloronicotinic acid. Results obtained by both methods were compared, MSPD showed higher recoveries and sensitivity than LLE for most pesticides, except for carbaryl. As MSPD is easier to perform, faster, consumes less sample and organic solvents than LLE, its application for pesticide analysis in honeybees is suggested.
Keywords
Honeybees , pesticides , metabolites , Liquid chromatography , mass spectrometry
Journal title
Talanta