Title of article :
Indirect thermal lens detection for capillary electrophoresis
Author/Authors :
Nedosekin، نويسنده , , D.A. and Bendrysheva، نويسنده , , S.N. and Faubel، نويسنده , , W. and Proskurnin، نويسنده , , M.A. and Pyell، نويسنده , , U.، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2007
Abstract :
Thermal lens detection with a 325.0 nm He–Cd excitation laser is used for thermooptical indirect detection in combination with the capillary electrophoretic separation of organic anions. The optimization of indirect thermooptical detection is discussed. With Mordant Yellow 7 (an azo dye) chosen as a probe ion limits of detection for 1-heptane-, 1-pentane-, 1-butane-, 1-propanesulfonic, and acetic acid at a level of n × 10−7 M were achieved with a separation electrolyte containing 50 μM of the probe ion and 5 mM Tris pH 9.90. A further increase in the detection sensitivity (twofold decrease in the limit of detection ) was obtained with a separation electrolyte containing a volume fraction of 20% acetonitrile.
Keywords :
Indirect thermooptical detection , Capillary electrophoresis , Thermal lens detection , Alkanesulfonic acids , Organo-aqueous separation electrolyte