• Title of article

    A Norwegian case study on the production of hydrogen from wind power

  • Author/Authors

    Greiner، نويسنده , , Christopher J. and Korpإs، نويسنده , , Magnus and Holen، نويسنده , , Arne T.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    8
  • From page
    1500
  • To page
    1507
  • Abstract
    A method for assessment of wind–hydrogen ( H 2 ) energy systems is presented. The method includes chronological simulations and economic calculations, enabling optimised component sizing and calculation of H 2 cost. System components include a wind turbine, electrolyser, compressor, storage tank and power converter. A case study on a Norwegian island is presented. The commuting ferry is modelled as a H 2 ferry, representing the H 2 demand. The evaluation includes a grid-connected system and an isolated system with a backup power generator. Simulation results show that much larger components are needed for the isolated system. H 2 cost amounted to 2.8 € / kg and 6.2 € / kg for the grid-connected and isolated system, respectively. Sensitivity analyses show that a marginal decrease in wind turbine and electrolyser cost will reduce the H 2 cost substantially. Rate of return is also important due to high investment costs. The grid-connected system is by far the most economical, but the system involves frequent grid interaction.
  • Keywords
    Modelling , Chronological simulation , Hydrogen economy , electrolysis , Renewable energy , Wind power , Distributed generation
  • Journal title
    International Journal of Hydrogen Energy
  • Serial Year
    2007
  • Journal title
    International Journal of Hydrogen Energy
  • Record number