Title of article :
Simultaneous determination of chromium(III) and cadmium(II) by differential pulse anodic stripping voltammetry on a stannum film electrode
Author/Authors :
Zhu، نويسنده , , Wei Wei and Li، نويسنده , , Nian Bing and Luo، نويسنده , , Hong Qun، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2007
Pages :
5
From page :
1733
To page :
1737
Abstract :
A stannum film electrode has been developed for the simultaneous determination of trace levels of chromium(III) and cadmium(II) by differential pulse anodic stripping voltammetry (DPASV). The stannum film electrode was generated in situ by depositing simultaneously the stannum film and the metals obtained by reduction of Cd(II) and Cr(III) at −1.4 V on a glassy carbon electrode. Then, the reduced products were oxidized by scanning the potential of the electrode from −1.4 to −0.4 V using DPASV. The electrode exhibited well-defined and separated stripping signals for both metals accompanied with a low background contribution. The possible mechanism of this design was proposed. Under the optimized working conditions, the detection limit was 2.0 and 1.1 μg l−1 for Cr(III) and Cd(II) at a deposition time of 3 min. Finally, the stannum film electrode was successfully applied to the determination of Cd(II) in tap water with satisfactory results.
Keywords :
Cadmium(II) , Differential pulse anodic stripping voltammetry , Stannum film electrode , Chromium(III)
Journal title :
Talanta
Serial Year :
2007
Journal title :
Talanta
Record number :
1652738
Link To Document :
بازگشت