Title of article :
On-line preconcentration and speciation analysis of inorganic vanadium in urine using l-methionine immobilised on controlled pore glass
Author/Authors :
Pacheco، نويسنده , , Pablo H. and Olsina، نويسنده , , Roberto A. and Smichowski، نويسنده , , Patricia Aguilar Martinez، نويسنده , , Luis D.، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2008
Abstract :
A study was undertaken to ascertain the analytical capabilities of combined ICP–OES with ultrasonic nebulization to perform on-line preconcentration and speciation of inorganic V species in urine samples using a micro-column packed with l-methionine immobilized on controlled pore glass (CPG) as solid phase extractant. At pH 5.0, l-methionine is selective only towards V(V) while, total vanadium was quantitatively adsorbed by the solid phase at pH 9.0 [as V(V)] due to V(IV) oxidation in alkali media. Vanadium species retained by l-methionine were quantitatively eluted from the column with 10% HCl. Effects of acidity, sample flow rate, concentration of eluent and interfering ions on the recovery of the analytes have been systematically investigated. The detection limit (3σ) of V is 0.008 ng mL−1 for USN–ICP–OES with an enhancement factor of 900 (10 for USN and 90 for l-methionine), and the relative standard deviation (R.S.D.) is better than 2%. The proposed method has been applied to the determination of inorganic V(V) and V(IV) in urine.
Keywords :
l-Methionine , vanadium , Speciation , USN–ICP–OES , urine