• Title of article

    Research of a HySyLab internal standard procedure for single PEMFC

  • Author/Authors

    Cuccaro، نويسنده , , Rugiada and Lucariello، نويسنده , , Marialaura and Battaglia، نويسنده , , Andrea and Graizzaro، نويسنده , , Alessandro، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    8
  • From page
    3159
  • To page
    3166
  • Abstract
    In literature there are many articles and documents discussing possible single PEMFC test protocols and some attempts to identify a good procedure to which conform, e.g. “single cell test protocol” (USFCC) or “PEFC testing procedures” (FCTESTNET). The Hydrogen System Laboratory (HySyLab) has identified an internal test protocol for a good PEMFC characterisation. In the paper the procedure is illustrated in all its aspects: the assembly, the conditioning and the characterisation of a single PEMFC through polarisation curves under different conditions of temperature, pressure and relative humidity. Other aspects like internal resistance and pressure drops are studied. The HySyLab procedure permits to obtain reproducible and excellent performances with commercial MEAs and PEMFCs tested in laboratory ( 2200 mA cm - 2 at 0.4 V at 70 ∘ C cell temperature, 100%RH, ambient pressure, λ air = 2.5 and λ H 2 = 1.5 ).
  • Keywords
    MEA , PEMFC , Polarisation curve , Assembling , test protocol
  • Journal title
    International Journal of Hydrogen Energy
  • Serial Year
    2008
  • Journal title
    International Journal of Hydrogen Energy
  • Record number