Title of article
Novel PVC membrane-based thoron ion selective electrode and its application: Determination of zirconium
Author/Authors
Arida، نويسنده , , Hassan A.، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2008
Pages
4
From page
40
To page
43
Abstract
The construction, electrochemical evaluation and application of new electrode selective to the thoron reagent are reported. The electrode incorporates bathophenanthroline iron: thoron ion pair as electroactive sensing material, o-nitrophenyl octyl ether as plasticizer and PVC as support matrix, exhibits a Nernstian response to thoron with a slope of −29.7 ± 1 mV per decade in a range of concentration from 1.0 × 10−6 to 5.0 × 10−2 mol L−1, a detection limit of 6.0 × 10−7 mol L−1 and fast response time of less than 30 s. The proposed electrode is successfully applied to zirconium ion determination in aqueous samples using indirect potentiometry and the results obtained are compared with those provided by spectrophotometric analysis using thoron as complexing agent.
Keywords
Thoron , Ion selective electrode , Indirect potentiometry , Zirconium determination