• Title of article

    Detection of methyl salicylate using polymer-filled chemicapacitors

  • Author/Authors

    Patel، نويسنده , , Sanjay V. and Hobson، نويسنده , , Stephen T. and Cemalovic، نويسنده , , Sabina and Mlsna، نويسنده , , Todd E.، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2008
  • Pages
    6
  • From page
    872
  • To page
    877
  • Abstract
    Methyl salicylate (MeS) is used as a chemical warfare agent simulant to test chemical protective garments and other individual personal protective gear. The accurate and real-time detection of this analyte is advantageous for various testing regimes. This paper reports the results of MeS vapor exposures on polymer-filled capacitance-based sensors at temperatures ranging from 15 °C to 50 °C under dry and humid conditions. Multiple capacitors were arranged in an array on a silicon chip each having a different sorptive polymer. The sensors used parallel-plate electrode geometry to measure the dielectric permittivity changes of each polymer when exposed to water and MeS vapor. Of the four polymers tested against MeS, the optimal polymer displayed near or sub-parts-per-million detection limits at 35 °C (0–80%RH).
  • Keywords
    Microsensors , sensor array , Man-in-Simulant Test , Capacitance measurement , Chemical transducers , methyl salicylate
  • Journal title
    Talanta
  • Serial Year
    2008
  • Journal title
    Talanta
  • Record number

    1655497