Title of article :
High fuel utilization operation of pure hydrogen fuel cells
Author/Authors :
Nishikawa، نويسنده , , H. and Sasou، نويسنده , , H. and Kurihara، نويسنده , , R. and Nakamura، نويسنده , , S. and Kano، نويسنده , , A. and Tanaka، نويسنده , , K. Roger Aoki، نويسنده , , T. and Ogami، نويسنده , , Y.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
8
From page :
6262
To page :
6269
Abstract :
For a fuel cell system using pure hydrogen as fuel, high hydrogen utilization operation is required because the exhausted hydrogen from the fuel cell is not used as a heat source for a reformer. While the hydrogen utilization is very high, any minor imbalance in the distributed flow causes a shortage of hydrogen gas. In order to achieve high hydrogen utilization operation, cells humidified at the cathode side, of counter flow type and with two-block divided stack where the hydrogen gas is fed to the first block with its exhaust hydrogen being fed to the second block have been developed. Five kilowatts class (100 cells) short stack systems fabricated to above specification showed stable operation at hydrogen utilizations up to 96%.
Keywords :
Humidity distribution , High hydrogen utilization operation , PEFC
Journal title :
International Journal of Hydrogen Energy
Serial Year :
2008
Journal title :
International Journal of Hydrogen Energy
Record number :
1656031
Link To Document :
بازگشت