Title of article
Determination of strontium and simultaneous determination of strontium oxide, magnesium oxide and calcium oxide content of Portland cement by derivative ratio spectrophotometry
Author/Authors
Idriss، نويسنده , , K.A. and Sedaira، نويسنده , , H. and Ahmed، نويسنده , , S.S.، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2009
Pages
7
From page
81
To page
87
Abstract
A derivative spectrophotometric method has been developed for the determination of strontium in Portland cement. The method is applied successfully for the simultaneous determination of SrO, MgO and CaO. It is based on the use of Alizarin Complexone (AC) as a complexing agent and measurement of the derivative ratio spectra of the analytes. Interferences of manganese(II) and zinc(II) were eliminated by precipitation. The validity of the method was examined by analyzing several Standard Reference Material (SRM) Portland cement samples. The strontium complex formed at pH 9.5 allows precise and accurate determination of strontium over the concentration range of 1.5–18 mg L−1 of strontium. The MDL (at 95% confidence level) was found to be 25 ng mL−1 for strontium in National Institute of Standards and Technology (NIST) cement samples using the proposed method.
Keywords
Strontium determination , Portland cement analysis , Derivative spectrophotometry
Journal title
Talanta
Serial Year
2009
Journal title
Talanta
Record number
1656696
Link To Document