Title of article :
Control of the ignition possibility of hydrogen by electrostatic discharge at a ventilation duct outlet
Author/Authors :
Imamura، نويسنده , , Tomohiko and Mogi، نويسنده , , Toshio and Wada، نويسنده , , Yuji، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
9
From page :
2815
To page :
2823
Abstract :
To control the ignition possibility of hydrogen by electrostatic discharge at a ventilation duct outlet, we investigated the effect of the outlet shape. Four types of outlets were designed; outlet A (6.35 mm pipe), outlet B (12.7 mm pipe), outlet C (25.4 mm pipe) and a tapered porous outlet (called TP outlet in this paper). Iron (III) oxide particles were used as the model dust. clarified that if the ventilation duct outlet is grounded, most of the electrostatic charges are not generated on the ventilation duct outlet. But, not all generation of electrostatic charges from the mixture of hydrogen and iron oxide can be removed by grounding only. However, the voltage and energy of the mixture at a certain downstream position can be reduced by using the TP outlet. This result means that the ignition possibility by electrostatic discharge may be reduced by using the TP outlet.
Keywords :
Ignition , Ventilation duct outlet , Hydrogen , Electrostatic charges
Journal title :
International Journal of Hydrogen Energy
Serial Year :
2009
Journal title :
International Journal of Hydrogen Energy
Record number :
1657450
Link To Document :
بازگشت