Title of article
Low temperature milling of the LiNH2 + LiH hydrogen storage system
Author/Authors
Osborn، نويسنده , , William and Markmaitree، نويسنده , , Tippawan and Shaw، نويسنده , , Leon L. and Hu، نويسنده , , Jian-Zhi and Kwak، نويسنده , , JaHun and Yang، نويسنده , , Zhenguo، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
9
From page
4331
To page
4339
Abstract
Ball milling of the LiNH2 + LiH storage system was performed at 20 °C, −40 °C, and −196 °C, and the resulting powders were analyzed using X-ray diffraction, scanning electron microscopy, nuclear magnetic resonance (NMR), specific surface area analysis, and kinetics cycling measurements. Ball milling at −40 °C showed no appreciable deviations from the 20 °C sample, but the −196 °C powder exhibited a significant increase in the hydrogen desorption kinetics. NMR analysis indicates that a possible explanation for the kinetics increase is the retention of internal defects generated during the milling process that are annealed at the collision site at higher milling temperatures.
Keywords
Hydrogen storage materials , Lithium amide , ball milling , Kinetics , hydride