• Title of article

    Determination of naproxen in human urine by high-performance liquid chromatography with direct electrogenerated chemiluminescence detection

  • Author/Authors

    Sun، نويسنده , , Yonghua and Zhang، نويسنده , , Zhujun and Xi، نويسنده , , Zhijun and Shi، نويسنده , , Zuolong، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2009
  • Pages
    5
  • From page
    676
  • To page
    680
  • Abstract
    A simple and sensitive liquid chromatographic method coupled with electrogenerated chemiluminescence (ECL) was described for the separation and quantification of naproxen in human urine. The method was based on the ECL of naproxen in basic NaNO3 solution with a dual-electrode system. Factors affected the ECL emission were investigated. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of naproxen in the range of 4.0 × 10−8 g mL−1 to 2.0 × 10−6 g mL−1 and the detection limit was 1.6 × 10−8 g mL−1 (S/N = 3). Application of the method to the analyses of naproxen in human urine proved feasible.
  • Keywords
    Liquid chromatography , Naproxen , Electrogenerated chemiluminescence , Dual-electrode system
  • Journal title
    Talanta
  • Serial Year
    2009
  • Journal title
    Talanta
  • Record number