Title of article :
Hydrogen storage in metal hydride tanks equipped with metal foam heat exchanger
Author/Authors :
Mellouli، نويسنده , , S. and Dhaou، نويسنده , , H. and Askri، نويسنده , , F. and Jemni، نويسنده , , A. and Ben Nasrallah، نويسنده , , S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
This paper presents a two-dimensional mathematical model to evaluate transient heat and mass transfer in a metal hydride tank (hereinafter MHT) with metal foam heat exchanger. The model is validated by comparison with experimental data. A good agreement is obtained.
y of the geometric and the operating parameters of the metal foam (such as base material, pore size and relative density) has been carried out to identify their influence on the performance of the charging process of the MHT. After that, the model was used as a tool to predict the performance of the hydrogen-charging process of two configurations of MHTs with metal foam heat exchangers. The obtained results showed that the reduction of the storage time due to the metal foam heat exchanger can be more important when the MHT is equipped with a concentric heat exchanger tube.
Keywords :
Hydrogen storage , metal foams , Metal hydrides tank , Heat exchangers , Time charging
Journal title :
International Journal of Hydrogen Energy
Journal title :
International Journal of Hydrogen Energy