• Title of article

    Selective and specific detection of sulfate-reducing bacteria using potentiometric stripping analysis

  • Author/Authors

    Wan ، نويسنده , , Yi and Zhang، نويسنده , , Dun and Hou، نويسنده , , Baorong، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2010
  • Pages
    4
  • From page
    1608
  • To page
    1611
  • Abstract
    A fast, sensitive and reliable potentiometric stripping analysis (PSA) is described for the selective detection of the marine pathogenic sulfate-reducing bacterium (SRB), Desulforibrio caledoiensis. The chemical and electrochemical parameters that exert influence on the deposition and stripping of lead ion, such as deposition potential, deposition time and pH value were carefully studied. The concentration of SRB was determined in acetate buffer solution (pH 5.2) under the optimized condition (deposition potential of −1.3 V, deposition time of 250 s, ionic strength of 0.2 mol L−1 and oxidant mercury (II) concentration of 40 mg L−1). A linear relationship between the stripping response and the logarithm of the bacterial concentration was observed in the range of 2.3 × 10 to 2.3 × 107 cfu mL−1. In addition, the potentiometric stripping technique gave a distinct response to the SRB, but had no obvious response to Escherichia coli. The measurement system has a potential for further applications and provides a facile and sample method for detection of pathogenic bacteria.
  • Keywords
    Potentiometric stripping analysis , Sulfate-Reducing Bacteria , Pathogenic bacteria detection , Sulfide
  • Journal title
    Talanta
  • Serial Year
    2010
  • Journal title
    Talanta
  • Record number