Title of article
Determination of bisphenol A and naphthols in river water samples by capillary zone electrophoresis after cloud point extraction
Author/Authors
Zhong، نويسنده , , Shuxian and Tan، نويسنده , , Swee Ngin and Ge، نويسنده , , Liya and Wang، نويسنده , , Weiping and Chen، نويسنده , , Jianrong، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2011
Pages
5
From page
488
To page
492
Abstract
As a first attempt, cloud point extraction (CPE) was developed to preconcentrate bisphenol A (BPA), α-naphthol and β-naphthol prior to performing capillary zone electrophoresis (CZE) analysis. The parameters influencing the CPE efficiency, such as Triton X-114 concentrations, pH value, extraction time and temperature were systematically evaluated.
diluting with acetonitrile, the surfactant-rich phase of CPE can be injected directly into the CE instrument. The CZE baseline separation was achieved with running buffer (pH 9.5) composed of 50 mM sodium tetraborate in 30% (v/v) methanol, and an applied voltage of 25 kV. Under the optimized CPE and CZE conditions, an preconcentration factor of 50 times could be obtained and the limit of quantification for the three analytes were found to be 1.67 μg L−1, 0.80 μg L−1 and 0.67 μg L−1 for BPA, α-naphthol and β-naphthol, respectively. The proposed methods have shown to be a green, rapid and effective approach for determination of three analytes present in river water samples.
Keywords
?-Naphthol , Cloud point extraction , Capillary zone electrophoresis , BISPHENOL A , ?-Naphthol
Journal title
Talanta
Serial Year
2011
Journal title
Talanta
Record number
1662732
Link To Document