• Title of article

    Sensitive detection of endocrine disrupters using ionic liquid – Single walled carbon nanotubes modified screen-printed based biosensors

  • Author/Authors

    Gurban، نويسنده , , Ana-Maria and Rotariu، نويسنده , , Lucian and Baibarac، نويسنده , , Mihaela and Baltog، نويسنده , , Ioan and Bala، نويسنده , , Camelia، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2011
  • Pages
    7
  • From page
    2007
  • To page
    2013
  • Abstract
    Simple and low cost biosensor based on screen-printed electrode for sensitive detection of some alkylphenols was developed, by entrapment of HRP in a nanocomposite gel based on single-walled carbon nanotubes (SWCNTs) and 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF6]) ionic liquid. Raman and FTIR spectroscopy, CV and EIS studies demonstrate the interaction between SWCNTs and ionic liquid. The nanocomposite gel, SWCNT–[BMIM][PF6] provides to the modified sensor a considerable enhanced electrocatalytic activity toward hydrogen peroxide reduction. The HRP based biosensor exhibits high sensitivity and good stability, allowing a detection of the alkylphenols at an applied potential of −0.2 V vs. Ag/AgCl, in linear range from 5.5 to 97.7 μM for 4-t-octylphenol and respectively, between 5.5 and 140 μM for 4-n-nonylphenol, with a response time of about 5 s. The detection limit was 1.1 μM for 4-t-octylphenol, and respectively 0.4 μM for 4-n-nonylphenol (S/N = 3).
  • Keywords
    single-walled carbon nanotubes , Ionic liquid , Screen-printed electrode , Enzyme , Alkylphenols
  • Journal title
    Talanta
  • Serial Year
    2011
  • Journal title
    Talanta
  • Record number