Title of article
Cobalt(II) selective membrane electrode based on palladium(II) dichloro acetylthiophene fenchone azine
Author/Authors
Isa، نويسنده , , I.M. and Mustafar، نويسنده , , S. and Ahmad، نويسنده , , M. and Hashim، نويسنده , , N. Abdul Ghani، نويسنده , , S.A.، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2011
Pages
5
From page
230
To page
234
Abstract
A new cobalt(II) ion selective electrode based on palladium(II) dichloro acetylthiophene fenchone azine(I) has been developed. The best membrane composition is found to be 10:60:10:21.1 (I)/PVC/NaTPB/DOP (w/w). The electrode exhibits a Nerstian response in the range of 1.0 × 10−1–1.0 × 10−6 M with a detection limit and slope of 8.0 × 10−7 M and 29.6 ± 0.2 mV per decade respectively. The response time is within the range of 20–25 s and can be used for a period of up to 4 months. The electrode developed reveals good selectivity for cobalt(II) and could be used in pH range of 3–7. The electrode has been successfully used in the determination of cobalt(II) in water samples.
Keywords
Cobalt(II) , membrane electrode , Palladium(II) dichloro acetylthiophene fenchone azine , PVC
Journal title
Talanta
Serial Year
2011
Journal title
Talanta
Record number
1663881
Link To Document