• Title of article

    An evaluation of uncertainty associated to analytical measurements of selected polycyclic aromatic compounds in ambient air

  • Author/Authors

    Barrado-Olmedo، نويسنده , , Ana Isabel and Pérez-Pastor، نويسنده , , Rosa Marيa and Garcيa-Alonso، نويسنده , , Susana، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2012
  • Pages
    7
  • From page
    428
  • To page
    434
  • Abstract
    This paper presents an evaluation of uncertainty associated to analytical measurement of 18 polycyclic aromatic compounds (PACs) in ambient air by liquid chromatography with fluorescence detection (HPLC/FD). The study was focused on analyses of PM10, PM2.5 and gas phase fractions. Main analytical uncertainty was estimated for 11 polycyclic aromatic hydrocarbons (PAHs), four nitro-polycyclic aromatic hydrocarbons (nitro-PAHs) and two hydroxy-polycyclic aromatic hydrocarbons (OH-PAHs) based on the analytical determination, reference material analysis and extraction step. Main contributions reached 15–30% and came from extraction process of real ambient samples, being those for nitro-PAHs the highest (20–30%). Range and mean concentration of selected PACs measured in gas phase and PM10/PM2.5 particle fractions during a full year are also presented. Concentrations of OH-PAHs were about 2–4 orders of magnitude lower than their parent PAHs and comparable to those sparsely reported in literature.
  • Keywords
    Ambient air , Hydroxy-PAHs , PAHS , Nitro-PAHs , HPLC , fluorescence
  • Journal title
    Talanta
  • Serial Year
    2012
  • Journal title
    Talanta
  • Record number