Title of article :
Anodic stripping voltammetric measurement of trace cadmium at tin-coated carbon paste electrode
Author/Authors :
Li، نويسنده , , Bang Lin and Wu، نويسنده , , Zhi Ling and Xiong، نويسنده , , Chang Hong and Luo، نويسنده , , Hong Qun and Li، نويسنده , , Nian Bing، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2012
Pages :
4
From page :
707
To page :
710
Abstract :
A carbon paste electrode modified with tin was used for the determination of trace cadmium by anodic stripping voltammetry. The electroanalytical performance for the determination of Cd(II) on the tin-coated carbon paste electrode(SnF-CPE) was better than that on the carbon paste electrode. The measuring conditions have been optimized. The measurement of trace cadmium on the SnF-CPE has the best response under the conditions of 0.10 mol L−1 acetate buffer solution (pH 3.9), 3.5 mg L−1 Sn(II), deposition potential of −1.40 V, and deposition time of 150 s. The SnF-CPE revealed highly linear behavior in the concentration range of 2.0–90.0 μg L−1 with the detection limit of 1.13 μg L−1 for Cd(II). The developed sensor has been applied to the determination of Cd(II) in real water samples with satisfactory results.
Keywords :
Stripping analysis , Tin film electrode , Carbon paste electrode , Cadmium(II) determination
Journal title :
Talanta
Serial Year :
2012
Journal title :
Talanta
Record number :
1664809
Link To Document :
بازگشت