Title of article
Diagnosis of scale up issues associated with planar solid oxide fuel cells
Author/Authors
Dey، نويسنده , , Tapobrata and Ghosh، نويسنده , , Prakash C. and Singdeo، نويسنده , , Debanand and Bose، نويسنده , , Manaswita and Basu، نويسنده , , Rajendra N.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
10
From page
9967
To page
9976
Abstract
One of the most important challenges faced by SOFC technology towards the commercialisation lies in the issues related to scale up. In this work, root cause analysis of performance loss in scaled up (1:50) SOFC is carried out. Reduction in actual contact area (6.7% on cathode and 2.5% on the anode) between the metallic interconnects and the cell, and non-uniformity of reactant distribution, are found to play critical roles towards the poor performance of the scaled up cell. Finally, suggestions are made to sustain the performance during the scale up.
Keywords
Planar SOFC , Scale up issues , contact resistance , CFD modelling
Journal title
International Journal of Hydrogen Energy
Serial Year
2011
Journal title
International Journal of Hydrogen Energy
Record number
1666877
Link To Document