Title of article :
An automatic flow system for NIR screening analysis of liquefied petroleum gas with respect to propane content
Author/Authors :
Dantas، نويسنده , , Hebertty V. and Barbosa، نويسنده , , Mayara F. and Nascimento، نويسنده , , Elaine C.L. and Moreira، نويسنده , , Pablo N.T. and Galvمo، نويسنده , , Roberto K.H. and Araْjo، نويسنده , , Mلrio C.U.، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2013
Pages :
5
From page :
158
To page :
162
Abstract :
This paper proposes a NIR spectrometric method for screening analysis of liquefied petroleum gas (LPG) samples. The proposed method is aimed at discriminating samples with low and high propane content, which can be useful for the adjustment of burn settings in industrial applications. A gas flow system was developed to introduce the LPG sample into a NIR flow cell at constant pressure. In addition, a gas chromatographer was employed to determine the propane content of the sample for reference purposes. The results of a principal component analysis, as well as a classification study using SIMCA (soft independent modeling of class analogies), revealed that the samples can be successfully discriminated with respect to propane content by using the NIR spectrum in the range 8100–8800 cm−1. In addition, by using SPA-LDA (linear discriminant analysis with variables selected by the successive projections algorithm), it was found that perfect discrimination can also be achieved by using only two wavenumbers (8215 and 8324 cm−1). This finding may be of value for the design of a dedicated, low-cost instrument for routine analyses.
Keywords :
Liquefied petroleum gas , Propane content , Near-infrared spectrometry , Multivariate classification
Journal title :
Talanta
Serial Year :
2013
Journal title :
Talanta
Record number :
1667067
Link To Document :
بازگشت