Title of article
Organic-phase enzyme electrode for phenolic determination based on a functionalized sol–gel composite
Author/Authors
Wang، نويسنده , , Bingquan and Dong، نويسنده , , Shaojun، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
6
From page
45
To page
50
Abstract
An amperometric biosensor for monitoring phenols in the organic phase was constructed by the silica sol–gel immobilization of tyrosinase on a glassy carbon electrode. The organic–inorganic hybrid materials with different sol–gel precursors and polymers were optimized, and the experimental conditions, such as the effect of the solvent, operational potential and enzyme loading were explored for the optimum analytical performance of the enzyme electrode. The biosensor can reach 95% of steady-state current in about 18 s, and the trend in the sensitivity of different phenols is as follows: catechol>phenol>p-cresol. In addition, the apparent Michaelis–Menten constants (Kmapp) and the stability of the enzyme electrode were discussed.
Keywords
Organic-phase biosensor , tyrosinase , Sol–gel method , Phenolic determination , Hybrid material
Journal title
Journal of Electroanalytical Chemistry
Serial Year
2000
Journal title
Journal of Electroanalytical Chemistry
Record number
1667499
Link To Document