• Title of article

    Poly[Fe(phen-NH2)3]2+ modified electrodes: proton-gated charge transfer reactions and applications in current rectification

  • Author/Authors

    Liou، نويسنده , , Yea Wenn and Wang، نويسنده , , Chong Mou، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    8
  • From page
    126
  • To page
    133
  • Abstract
    Poly[Fe(phen-NH2)3]2+ electrodes were prepared on Au-sputtered quartz crystals (9 MHz) by oxidizing iron(II) tris(5-amino-1,10-phenanthroline) (denoted Fe(phen-NH2)32+) complex in acetonitrile. According to the study with the electrochemical quartz crystal microbalance (EQCM) technique, the decisive step in this electrode preparation involved an anodic polymerization. The resulting polymer (denoted poly[Fe(phen-NH2)3]2+) as prepared on the electrodes showed two redox waves in aqueous solutions. One was ascribed to the electron removal from the metal center (FeII), poly[Fe(phen-NH2)3]3+/2+, and the other one to an electron addition to the resulting polymer, poly[Fe(phen-NH2)3]2+/+. For the latter waves, the peak potential shifted to more negative values in a linear manner with an increased pH. From the slope (ca. 72 mV pH−1) and the half-height-peak width (W1/2≈120 mV), a one-electron-one-proton transfer reaction was ascribed. Because of this property, the poly[Fe(phen-NH2)3]2+ electrode behaved as a pH sensor. The sensitivity covered a pH range from 2 to 10. Energetic probing with Fe(CN)63−/4−, Ru(NH3)63+/2+ and methylviologen (MV2+/+/0), in addition, revealed that this pH dependence could be employed to regulate the electron transfer taking place through the polyFe(phen-NH2)32+ film. As a result, current rectifications for Fe(CN)63−/4− and Ru(NH3)63+/2+ were achieved. In this study a short-range interaction between MV2+ and the polymeric Fe(phen-NH2)32+ film was also found. The associated Gibbs energy change was estimated to be −33 kJ. Long-term experiments, in addition, suggested that although a decrease in pH might deactivate the electrochemical activity of the adsorbate, the adsorbed MV2+ did not diffuse away from the electrode. In consequence, a vivid ‘on-off’ pattern in terms of current versus time was found during the variation in pH.
  • Keywords
    Current rectification , EQCM , pH sensing , Energetic probing
  • Journal title
    Journal of Electroanalytical Chemistry
  • Serial Year
    2001
  • Journal title
    Journal of Electroanalytical Chemistry
  • Record number

    1667725