Title of article
Maintaining desired level of relative humidity throughout a fuel cell with spatially variable heat removal rates
Author/Authors
Ivan Tolj، نويسنده , , Ivan and Bezmalinovic، نويسنده , , Dario and Barbir، نويسنده , , Frano، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
9
From page
13105
To page
13113
Abstract
A concept of using the product water to internally humidify the air stream in a PEM fuel cell without external humidification is investigated by a simple, pseudo 2-D model along a single channel. This model takes into account the mass and energy balance, water and heat generation rates, heat removal, and water transport through the membrane. The model and thus the concept were confirmed experimentally using a 5-segment fuel cell. The temperature of each segment could be individually controlled, and the temperature and humidity of air could be measured between each segment. A temperature profile has been established, by applying spatially variable heat removal rates along the cathode channel, that results in relative humidity being close to 100% throughout the cell without any external humidification. The concept may be applied to a fuel cell stack resulting in simplification of the suporting system by avoiding external humidification.
Keywords
Segmented model , Humid air Mollier diagram , PEM fuel cell , Water management , Relative humidity
Journal title
International Journal of Hydrogen Energy
Serial Year
2011
Journal title
International Journal of Hydrogen Energy
Record number
1667798
Link To Document