Title of article :
Double potential step chronoamperometry at microdisk electrodes: simulating the case of unequal diffusion coefficients
Author/Authors :
Klymenko، نويسنده , , Oleksiy V. and Evans، نويسنده , , Russell G. and Hardacre، نويسنده , , Christopher and Svir، نويسنده , , Irina B. and Compton، نويسنده , , Richard G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
An efficient approach to the simulation of the double potential step chronoamperometry at a microdisk electrode based on an exponentially expanding time grid and conformal mapping of the space is presented. The dimensionless second potential step flux data are included as a function of the first potential step duration and the ratio of the diffusion coefficients of the reacting species allowing instant analysis of the experimental double potential step chronoamperograms without a need for simulation. The values of the diffusion coefficients are determined for several test systems and found to be in good agreement with existing literature data.
Keywords :
Unequal diffusion coefficients , SIMULATION , Double potential step chronoamperometry , Microdisk electrode